UCT206 Bearing Dimensions
UCT206 take up bearing unit: 30 mm bore, T206 housing + UC206 insert. Frame dimensions from FULI's catalog, designation and size-equivalent codes.
UCT206 specifications
| Shaft diameter d | 30 mm |
|---|---|
| Dimension H | 102 mm |
| Dimension L | 113 mm |
| Dimension L1 | 70 mm |
| Dimension N2 | 37 mm |
| Insert width B | 38.1 mm |
| Seal / shield options | Sealed insert bearing (UC type) with cast iron housing |
| Material | Insert: GCr15 chrome bearing steel (rings and rolling elements); housing: cast iron |
| Precision | P0 (standard) |
| Radial clearance | C0 (standard); C3 on request |
Dimensions from FULI's catalog. Letters follow the dimension drawing in FULI's catalog; ask us for the drawing.
Load ratings & speed
| Dynamic load rating Cr | 19.5 kN |
|---|---|
| Static load rating C0r | 11.3 kN |
| Limiting speed, shaft js7 / j7 | 4,700 rpm |
| Limiting speed, shaft h7 | 3,400 rpm |
| Weight | 1.3 kg — approx. |
Values from FULI's catalog; confirm for your application.
How to read the UCT206 designation
| Segment | Meaning |
|---|---|
| UC | Insert bearing with set-screw locking and spherical outside diameter |
| T | Take-up housing (slides in a frame to tension a belt or chain) |
| 2 | 200 series (light duty) |
| 06 | Bore code 06 → 30 mm bore. ISO bore code (00–03 = 10/12/15/17 mm; 04 and above = code × 5 mm). |
UCT206 interchange
UCT206 is a housed unit: a UC206 insert bearing in a T206 housing. The insert bearing dimensions follow ISO and interchange between manufacturers. Housing dimensions such as bolt hole spacing can differ between the JIS and ISO versions of the same designation, so please confirm the mounting dimensions with us before ordering.
Brand names are trademarks of their respective owners. FULI is not affiliated with, authorized by or endorsed by these companies. Part numbers are shown for interchange reference only. FULI dimensions, load ratings and speeds come from the FULI catalog.
UCT206 compared with nearby sizes and housings
UCT206 is a take-up unit that holds the UC206 insert on a 30 mm shaft: dimension H 102 mm, dimension L 113 mm, dimension L1 70 mm and dimension N2 37 mm.
The same 206 size is also made as UCP206 (pillow block unit, d 30 · H 42.9 · J 121 mm), UCF206 (square flange unit, d 30 · L 108 · J 83 mm) and UCFL206 (oval flange unit, d 30 · L 148 · J 117 mm). All of them take the same UC206 insert, so a worn insert can be changed without changing the housing type.
UCT210 is the next larger size in the same series on this site: shaft d 50 mm (20 mm more), inner ring width B 51.6 mm (13.5 mm more), dimension H 117 mm (15 mm more) and dimension L 149 mm (36 mm more).
| Model | Type | Main dimensions | Weight (kg) |
|---|---|---|---|
| UCT206 | take-up unit (this page) | d 30 · H 102 · L 113 mm | 1.3 |
| UCT210 | take-up unit | d 50 · H 117 · L 149 mm | 2.6 |
| UC206 | insert bearing | 30 × 62 × 38.1 mm (d × D × B) | 0.32 |
| SB206 | insert bearing | 30 × 62 × 30 mm (d × D × B) | — |
| SA206 | insert bearing | 30 × 62 × 23.8 mm (d × D × B) | — |
| UCP206 | pillow block unit | d 30 · H 42.9 · J 121 mm | 1.3 |
| UCF206 | square flange unit | d 30 · L 108 · J 83 mm | — |
| UCFL206 | oval flange unit | d 30 · L 148 · J 117 mm | — |
Dimensions in mm from the model pages; weight from FULI's catalog, — = not listed on this site.
UCT206 weight, load ratings and speed
FULI's catalog gives about 1.3 kg for the complete unit, housing and insert together, so 100 pieces of UCT206 weigh about 130 kg before packing.
The catalog lists UCT206 with a dynamic load rating of 19.5 kN and a static load rating of 11.3 kN. Its speed limits depend on the shaft tolerance: 4,700 rpm on a js7 or j7 shaft and 3,400 rpm on an h7 shaft. A closer shaft fit holds the inner ring more evenly, which is why the js7 / j7 figure is higher.
Values from FULI's catalog; confirm for your application.
UCT206 dimensions in inches
The nearest common inch shaft size to the 30 mm bore of UCT206 is 1-3/16 in (30.16 mm), 0.16 mm larger than the bore, so UCT206 will not go on it. An inch shaft needs an inch bore insert. Inch bore versions are made for some sizes; ask us with the shaft size.
| Dimension | Millimetres | Inches |
|---|---|---|
| Shaft diameter d | 30 mm | 1.1811 in |
| Dimension H | 102 mm | 4.0157 in |
| Dimension L | 113 mm | 4.4488 in |
| Dimension L1 | 70 mm | 2.7559 in |
| Dimension N2 | 37 mm | 1.4567 in |
| Insert width B | 38.1 mm | 1.5000 in |
Converted at 1 in = 25.4 mm and rounded to four decimals. The bearing itself is made to the millimetre sizes.
Mounting UCT206 (general guidance)
General guidance, not a FULI specification: insert bearings slide onto the shaft rather than being pressed on, and are held by their locking device. A shaft ground or drawn to h7 is common; a closer shaft such as js7 or j7 suits higher speed. For UCT206 the catalog gives 4,700 and 3,400 rpm for the two cases.
The UC206 insert in UCT206 is locked by set screws in the extended inner ring. Housed-unit problems usually start at the set screws: if the inner ring is not held, it turns on the shaft and wears it. Tighten each screw to the torque in the mounting instructions, and check them again after the first hours of running.
The housing of UCT206 slides in the guides of the frame. Set the belt or chain tension with the adjusting screw first, then lock the insert to the shaft.
Grease for UCT206
The insert in UCT206 is sealed on both sides and greased at the factory. If the housing has a grease fitting, add grease slowly through it while the shaft turns until a little fresh grease shows at the seals; general practice is to relubricate more often in wet or dusty places.
Greases for a stated temperature range can be specified on the order; for North America a range of −40 to 120 °C is often asked for.
How FULI supplies UCT206
FULI supplies UCT206 as a complete unit, or the UC206 insert on its own for replacement. Before packing, the factory checks the mounting torque, the fit of the insert in the housing, the radial clearance and that the base-to-centre height is consistent across the batch.
Rings are marked with a brand you are authorised to use, with the FULI brand, or left neutral, as your order states. The box is printed with the model, precision class and brand.
Inquiries that leave out the prefix or suffix letters are the usual cause of a wrong quote, so write the full designation, for example UCT206.
Tools and guides for UCT206
Typical applications
- Belt conveyor take-up (tail) pulleys
- Screw conveyors and bucket elevators
- Chain and belt tensioning on agricultural machinery
FAQ
What shaft size does UCT206 fit?
A 30 mm shaft (1.1811 in).
What is the difference between UCT206 and UCT210?
UCT210 is the next size up, for a 50 mm shaft, with inner ring width B 51.6 mm (13.5 mm more), dimension H 117 mm (15 mm more) and dimension L 149 mm (36 mm more). Choose UCT210 when the shaft is larger or the load is higher; the housings are not interchangeable.
Which insert fits UCT206?
The UC206 insert (30 × 62 × 38.1 mm). It is sold on its own for replacement.
UCT206 or UCP206: which should I use?
Both hold the same UC206 insert on a 30 mm shaft. UCT206 is a take-up unit (d 30 · H 102 · L 113 mm); UCP206 is a pillow block unit (d 30 · H 42.9 · J 121 mm). Choose by how the bearing is fixed to the machine: a pillow block bolts to a surface parallel to the shaft, a flange to a face across it.
How much does UCT206 weigh?
About 1.3 kg in FULI's catalog; 100 pieces weigh about 130 kg before packing.
Does UCT206 come as a complete unit or insert only?
UCT206 is normally supplied as a complete unit (insert bearing already fitted in the housing). The insert can also be quoted separately if you are replacing only the bearing.