Flange bearing unit

UCFL206 Bearing Dimensions

UCFL206 2-bolt oval flange bearing unit: 30 mm bore, 117 mm bolt centres. FL206 housing + UC206 insert, designation, size-equivalent codes.

UCFL206 flange bearing unit — representative image

UCFL206 specifications

Shaft diameter d 30 mm
Flange length L 148 mm
Bolt hole spacing J 117 mm
Flange width H 80 mm
Insert width B 38.1 mm
Mounting bolt M14
Seal / shield options Sealed insert bearing (UC type) with cast iron housing
Material Insert: GCr15 chrome bearing steel (rings and rolling elements); housing: cast iron
Precision P0 (standard)
Radial clearance C0 (standard); C3 on request
Load ratings Load ratings for this model are being checked against FULI's catalog. Ask for them with the quote.

Dimensions cross-checked against published catalogues; please confirm with your quote.

How to read the UCFL206 designation

SegmentMeaning
UCInsert bearing with set-screw locking and spherical outside diameter
FLTwo-bolt oval flange housing
2200 series (light duty)
06Bore code 06 → 30 mm bore. ISO bore code (00–03 = 10/12/15/17 mm; 04 and above = code × 5 mm).

UCFL206 interchange by brand

UCFL206 is a housed unit: a UC206 insert bearing in an FL206 housing. The insert bearing dimensions follow ISO and interchange between manufacturers. Housing dimensions such as bolt hole spacing can differ between the JIS and ISO versions of the same designation, so please confirm the mounting dimensions with us before ordering.

BrandDesignation
SKFUCFL 206
TimkenUCFL206
KoyoUCFL206

Same designation; confirm housing bolt spacing.

Brand numbers for UCP, UCF and UCFL units: Pillow Block Bearing Cross Reference.

Brand names are trademarks of their respective owners. FULI is not affiliated with, authorized by or endorsed by these companies. Part numbers are shown for interchange reference only. FULI dimensions, load ratings and speeds come from the FULI catalog.

UCFL206 compared with nearby sizes and housings

UCFL206 is a oval flange unit that holds the UC206 insert on a 30 mm shaft: flange length L 148 mm and flange width H 80 mm with M14 bolts.

The same 206 size is also made as UCP206 (pillow block unit, d 30 · H 42.9 · J 121 mm) and UCF206 (square flange unit, d 30 · L 108 · J 83 mm). All of them take the same UC206 insert, so a worn insert can be changed without changing the housing type.

UCFL207 is the next larger size in the same series on this site: shaft d 35 mm (5 mm more), inner ring width B 42.9 mm (4.8 mm more), length L 161 mm (13 mm more) and bolt spacing J 130 mm (13 mm more).

UCFL205 is the next smaller size in the same series on this site: shaft d 25 mm (5 mm less), inner ring width B 34.1 mm (4 mm less), length L 130 mm (18 mm less) and bolt spacing J 99 mm (18 mm less).

ModelTypeMain dimensionsWeight (kg)
UCFL206oval flange unit (this page)d 30 · L 148 · J 117 mm—
UCFL205oval flange unitd 25 · L 130 · J 99 mm—
UCFL207oval flange unitd 35 · L 161 · J 130 mm—
UC206insert bearing30 × 62 × 38.1 mm (d × D × B)0.32
SB206insert bearing30 × 62 × 30 mm (d × D × B)—
SA206insert bearing30 × 62 × 23.8 mm (d × D × B)—
UCP206pillow block unitd 30 · H 42.9 · J 121 mm1.3
UCF206square flange unitd 30 · L 108 · J 83 mm—

Dimensions in mm from the model pages; weight from FULI's catalog, — = not listed on this site.

UCFL206 load ratings

FULI's catalog has no load rating line for UCFL206 itself, so none is given here. The ratings of the UC206 insert are on its own page. Ask us and we send the figures with the quotation.

UCFL206 dimensions in inches

The nearest common inch shaft size to the 30 mm bore of UCFL206 is 1-3/16 in (30.16 mm), 0.16 mm larger than the bore, so UCFL206 will not go on it. An inch shaft needs an inch bore insert. Inch bore versions are made for some sizes; ask us with the shaft size.

DimensionMillimetresInches
Shaft diameter d30 mm1.1811 in
Flange length L148 mm5.8268 in
Bolt hole spacing J117 mm4.6063 in
Flange width H80 mm3.1496 in
Insert width B38.1 mm1.5000 in

Converted at 1 in = 25.4 mm and rounded to four decimals. The bearing itself is made to the millimetre sizes.

Mounting UCFL206 (general guidance)

General guidance, not a FULI specification: insert bearings slide onto the shaft rather than being pressed on, and are held by their locking device. A shaft ground or drawn to h7 is common; a closer shaft such as js7 or j7 suits higher speed.

The UC206 insert in UCFL206 is locked by set screws in the extended inner ring. Housed-unit problems usually start at the set screws: if the inner ring is not held, it turns on the shaft and wears it. Tighten each screw to the torque in the mounting instructions, and check them again after the first hours of running.

Bolt UCFL206 down with M14 bolts at 117 mm spacing on a flat, rigid face. Line up the two housings on a shaft before tightening the bolts fully, then lock the inserts, so the shaft is not bent between them.

Grease for UCFL206

The insert in UCFL206 is sealed on both sides and greased at the factory. If the housing has a grease fitting, add grease slowly through it while the shaft turns until a little fresh grease shows at the seals; general practice is to relubricate more often in wet or dusty places.

Greases for a stated temperature range can be specified on the order; for North America a range of −40 to 120 °C is often asked for.

How FULI supplies UCFL206

FULI supplies UCFL206 as a complete unit, or the UC206 insert on its own for replacement. Before packing, the factory checks the mounting torque, the fit of the insert in the housing, the radial clearance and that the base-to-centre height is consistent across the batch.

Rings are marked with a brand you are authorised to use, with the FULI brand, or left neutral, as your order states. The box is printed with the model, precision class and brand.

Inquiries that leave out the prefix or suffix letters are the usual cause of a wrong quote, so write the full designation, for example UCFL206.

Typical applications

  • Conveyors
  • Packaging machinery
  • Agricultural machinery
  • Textile machinery

FAQ

What shaft size does UCFL206 fit?

A 30 mm shaft (1.1811 in).

What is the difference between UCFL206 and UCFL207?

UCFL207 is the next size up, for a 35 mm shaft, with inner ring width B 42.9 mm (4.8 mm more), length L 161 mm (13 mm more) and bolt spacing J 130 mm (13 mm more). Choose UCFL207 when the shaft is larger or the load is higher; the housings are not interchangeable.

Which insert fits UCFL206?

The UC206 insert (30 × 62 × 38.1 mm). It is sold on its own for replacement.

UCFL206 or UCP206: which should I use?

Both hold the same UC206 insert on a 30 mm shaft. UCFL206 is a oval flange unit (d 30 · L 148 · J 117 mm); UCP206 is a pillow block unit (d 30 · H 42.9 · J 121 mm). Choose by how the bearing is fixed to the machine: a pillow block bolts to a surface parallel to the shaft, a flange to a face across it.

Does UCFL206 come as a complete unit or insert only?

UCFL206 is normally supplied as a complete unit (insert bearing already fitted in the housing). The insert can also be quoted separately if you are replacing only the bearing.

Where are the load ratings for UCFL206?

Load ratings for UCFL206 are being checked against FULI's catalog and are not shown on this page yet. Model pages with a "Load ratings & speed" table carry values from FULI's catalog.

Request a quote for UCFL206

WhatsApp instead

Your inquiry goes to sales@fuli-bearings.com.

Email us Chat on WhatsApp