Flange bearing unit

UCFL205 Bearing Dimensions

UCFL205 2-bolt oval flange bearing unit: 25 mm bore, 99 mm bolt centres. FL205 housing + UC205 insert, designation, size-equivalent codes.

UCFL205 flange bearing unit — representative image

UCFL205 specifications

Shaft diameter d 25 mm
Flange length L 130 mm
Bolt hole spacing J 99 mm
Flange width H 68 mm
Insert width B 34.1 mm
Mounting bolt M14
Seal / shield options Sealed insert bearing (UC type) with cast iron housing
Material Insert: GCr15 chrome bearing steel (rings and rolling elements); housing: cast iron
Precision P0 (standard)
Radial clearance C0 (standard); C3 on request
Load ratings Load ratings for this model are being checked against FULI's catalog. Ask for them with the quote.

Dimensions cross-checked against published catalogues; please confirm with your quote.

How to read the UCFL205 designation

SegmentMeaning
UCInsert bearing with set-screw locking and spherical outside diameter
FLTwo-bolt oval flange housing
2200 series (light duty)
05Bore code 05 → 25 mm bore. ISO bore code (00–03 = 10/12/15/17 mm; 04 and above = code × 5 mm).

UCFL205 interchange by brand

UCFL205 is a housed unit: a UC205 insert bearing in an FL205 housing. The insert bearing dimensions follow ISO and interchange between manufacturers. Housing dimensions such as bolt hole spacing can differ between the JIS and ISO versions of the same designation, so please confirm the mounting dimensions with us before ordering.

BrandDesignation
SKFUCFL 205
TimkenUCFL205
KoyoUCFL205

Same designation; confirm housing bolt spacing.

Brand numbers for UCP, UCF and UCFL units: Pillow Block Bearing Cross Reference.

Brand names are trademarks of their respective owners. FULI is not affiliated with, authorized by or endorsed by these companies. Part numbers are shown for interchange reference only. FULI dimensions, load ratings and speeds come from the FULI catalog.

UCFL205 compared with nearby sizes and housings

UCFL205 is a oval flange unit that holds the UC205 insert on a 25 mm shaft: flange length L 130 mm and flange width H 68 mm with M14 bolts.

The same 205 size is also made as UCP205 (pillow block unit, d 25 · H 36.5 · J 105 mm) and UCF205 (square flange unit, d 25 · J 70 mm (JIS)). All of them take the same UC205 insert, so a worn insert can be changed without changing the housing type.

UCFL206 is the next larger size in the same series on this site: shaft d 30 mm (5 mm more), inner ring width B 38.1 mm (4 mm more), length L 148 mm (18 mm more) and bolt spacing J 117 mm (18 mm more).

UCFL204 is the next smaller size in the same series on this site: shaft d 20 mm (5 mm less), inner ring width B 31 mm (3.1 mm less), length L 113 mm (17 mm less) and bolt spacing J 90 mm (9 mm less), and it takes M10 bolts instead of M14.

ModelTypeMain dimensionsWeight (kg)
UCFL205oval flange unit (this page)d 25 · L 130 · J 99 mm—
UCFL204oval flange unitd 20 · L 113 · J 90 mm—
UCFL206oval flange unitd 30 · L 148 · J 117 mm—
UC205insert bearing25 × 52 × 34.1 mm (d × D × B)0.21
SB205insert bearing25 × 52 × 27 mm (d × D × B)—
SA205insert bearing25 × 52 × 21.5 mm (d × D × B)—
UCP205pillow block unitd 25 · H 36.5 · J 105 mm0.8
UCF205square flange unitd 25 · J 70 mm (JIS)0.9

Dimensions in mm from the model pages; weight from FULI's catalog, — = not listed on this site.

UCFL205 load ratings

FULI's catalog has no load rating line for UCFL205 itself, so none is given here. The ratings of the UC205 insert are on its own page. Ask us and we send the figures with the quotation.

UCFL205 dimensions in inches

The nearest common inch shaft size to the 25 mm bore of UCFL205 is 1 in (25.40 mm), 0.4 mm larger than the bore, so UCFL205 will not go on it. An inch shaft needs an inch bore insert. Inch bore versions are made for some sizes; ask us with the shaft size.

DimensionMillimetresInches
Shaft diameter d25 mm0.9843 in
Flange length L130 mm5.1181 in
Bolt hole spacing J99 mm3.8976 in
Flange width H68 mm2.6772 in
Insert width B34.1 mm1.3425 in

Converted at 1 in = 25.4 mm and rounded to four decimals. The bearing itself is made to the millimetre sizes.

Mounting UCFL205 (general guidance)

General guidance, not a FULI specification: insert bearings slide onto the shaft rather than being pressed on, and are held by their locking device. A shaft ground or drawn to h7 is common; a closer shaft such as js7 or j7 suits higher speed.

The UC205 insert in UCFL205 is locked by set screws in the extended inner ring. Housed-unit problems usually start at the set screws: if the inner ring is not held, it turns on the shaft and wears it. Tighten each screw to the torque in the mounting instructions, and check them again after the first hours of running.

Bolt UCFL205 down with M14 bolts at 99 mm spacing on a flat, rigid face. Line up the two housings on a shaft before tightening the bolts fully, then lock the inserts, so the shaft is not bent between them.

Grease for UCFL205

The insert in UCFL205 is sealed on both sides and greased at the factory. If the housing has a grease fitting, add grease slowly through it while the shaft turns until a little fresh grease shows at the seals; general practice is to relubricate more often in wet or dusty places.

Greases for a stated temperature range can be specified on the order; for North America a range of −40 to 120 °C is often asked for.

How FULI supplies UCFL205

FULI supplies UCFL205 as a complete unit, or the UC205 insert on its own for replacement. Before packing, the factory checks the mounting torque, the fit of the insert in the housing, the radial clearance and that the base-to-centre height is consistent across the batch.

Rings are marked with a brand you are authorised to use, with the FULI brand, or left neutral, as your order states. The box is printed with the model, precision class and brand.

Inquiries that leave out the prefix or suffix letters are the usual cause of a wrong quote, so write the full designation, for example UCFL205.

Typical applications

  • Conveyors
  • Packaging machinery
  • Agricultural machinery
  • Textile machinery

FAQ

What shaft size does UCFL205 fit?

A 25 mm shaft (0.9843 in).

What is the difference between UCFL205 and UCFL206?

UCFL206 is the next size up, for a 30 mm shaft, with inner ring width B 38.1 mm (4 mm more), length L 148 mm (18 mm more) and bolt spacing J 117 mm (18 mm more). Choose UCFL206 when the shaft is larger or the load is higher; the housings are not interchangeable.

Which insert fits UCFL205?

The UC205 insert (25 × 52 × 34.1 mm). It is sold on its own for replacement.

UCFL205 or UCP205: which should I use?

Both hold the same UC205 insert on a 25 mm shaft. UCFL205 is a oval flange unit (d 25 · L 130 · J 99 mm); UCP205 is a pillow block unit (d 25 · H 36.5 · J 105 mm). Choose by how the bearing is fixed to the machine: a pillow block bolts to a surface parallel to the shaft, a flange to a face across it.

Does UCFL205 come as a complete unit or insert only?

UCFL205 is normally supplied as a complete unit (insert bearing already fitted in the housing). The insert can also be quoted separately if you are replacing only the bearing.

Where are the load ratings for UCFL205?

Load ratings for UCFL205 are being checked against FULI's catalog and are not shown on this page yet. Model pages with a "Load ratings & speed" table carry values from FULI's catalog.

Request a quote for UCFL205

WhatsApp instead

Your inquiry goes to sales@fuli-bearings.com.

Email us Chat on WhatsApp