Take-up bearing unit

UCT326 Bearing Dimensions

UCT326 take up bearing unit: 130 mm bore, T326 housing + UC326 insert. Frame dimensions H 385 / L 465 mm, designation and size-equivalent codes.

UCT326 take-up bearing unit — representative image

UCT326 specifications

Shaft diameter d 130 mm
Dimension H 385 mm
Dimension L 465 mm
Dimension L1 285 mm
Dimension N2 150 mm
Insert width B 135 mm
Seal / shield options Sealed insert bearing (UC type) with cast iron housing
Material Insert: GCr15 chrome bearing steel (rings and rolling elements); housing: cast iron
Precision P0 (standard)
Radial clearance C0 (standard); C3 on request
Load ratings Load ratings for this model are being checked against FULI's catalog. Ask for them with the quote.

Dimensions cross-checked against published catalogues; please confirm with your quote. Letters follow the dimension drawing in FULI's catalog; ask us for the drawing.

How to read the UCT326 designation

SegmentMeaning
UCInsert bearing with set-screw locking and spherical outside diameter
TTake-up housing (slides in a frame to tension a belt or chain)
3300 series (medium duty)
26Bore code 26 → 130 mm bore. ISO bore code (00–03 = 10/12/15/17 mm; 04 and above = code × 5 mm).

UCT326 interchange

UCT326 is a housed unit: a UC326 insert bearing in a T326 housing. The insert bearing dimensions follow ISO and interchange between manufacturers. Housing dimensions such as bolt hole spacing can differ between the JIS and ISO versions of the same designation, so please confirm the mounting dimensions with us before ordering.

Brand names are trademarks of their respective owners. FULI is not affiliated with, authorized by or endorsed by these companies. Part numbers are shown for interchange reference only. FULI dimensions, load ratings and speeds come from the FULI catalog.

UCT326 compared with nearby sizes and housings

UCT326 is a take-up unit that holds the UC326 insert on a 130 mm shaft: dimension H 385 mm, dimension L 465 mm, dimension L1 285 mm and dimension N2 150 mm.

The same 326 size is also made as UCP326 (pillow block unit, d 130 · H 180 · J 480 mm) and UCFL326 (oval flange unit, d 130 · L 550 · J 460 mm). All of them take the same UC326 insert, so a worn insert can be changed without changing the housing type.

UCT328 is the next larger size in the same series on this site: shaft d 140 mm (10 mm more), inner ring width B 145 mm (10 mm more), dimension H 415 mm (30 mm more) and dimension L 515 mm (50 mm more).

UCT321 is the next smaller size in the same series on this site: shaft d 105 mm (25 mm less), inner ring width B 112 mm (23 mm less), dimension H 290 mm (95 mm less) and dimension L 345 mm (120 mm less).

ModelTypeMain dimensionsWeight (kg)
UCT326take-up unit (this page)d 130 · H 385 · L 465 mm—
UCT321take-up unitd 105 · H 290 · L 345 mm—
UCT328take-up unitd 140 · H 415 · L 515 mm—
UC326insert bearing130 × 280 × 135 mm (d × D × B)—
UCP326pillow block unitd 130 · H 180 · J 480 mm—
UCFL326oval flange unitd 130 · L 550 · J 460 mm—

Dimensions in mm from the model pages; weight from FULI's catalog, — = not listed on this site.

UCT326 load ratings

FULI's catalog has no load rating line for UCT326 itself, so none is given here. The ratings of the UC326 insert are on its own page. Ask us and we send the figures with the quotation.

UCT326 dimensions in inches

The nearest common inch shaft size to the 130 mm bore of UCT326 is 5-1/8 in (130.18 mm), 0.18 mm larger than the bore, so UCT326 will not go on it. An inch shaft needs an inch bore insert. Inch bore versions are made for some sizes; ask us with the shaft size.

DimensionMillimetresInches
Shaft diameter d130 mm5.1181 in
Dimension H385 mm15.1575 in
Dimension L465 mm18.3071 in
Dimension L1285 mm11.2205 in
Dimension N2150 mm5.9055 in
Insert width B135 mm5.3150 in

Converted at 1 in = 25.4 mm and rounded to four decimals. The bearing itself is made to the millimetre sizes.

Mounting UCT326 (general guidance)

General guidance, not a FULI specification: insert bearings slide onto the shaft rather than being pressed on, and are held by their locking device. A shaft ground or drawn to h7 is common; a closer shaft such as js7 or j7 suits higher speed.

The UC326 insert in UCT326 is locked by set screws in the extended inner ring. Housed-unit problems usually start at the set screws: if the inner ring is not held, it turns on the shaft and wears it. Tighten each screw to the torque in the mounting instructions, and check them again after the first hours of running.

The housing of UCT326 slides in the guides of the frame. Set the belt or chain tension with the adjusting screw first, then lock the insert to the shaft.

Grease for UCT326

The insert in UCT326 is sealed on both sides and greased at the factory. If the housing has a grease fitting, add grease slowly through it while the shaft turns until a little fresh grease shows at the seals; general practice is to relubricate more often in wet or dusty places.

Greases for a stated temperature range can be specified on the order; for North America a range of −40 to 120 °C is often asked for.

How FULI supplies UCT326

FULI supplies UCT326 as a complete unit, or the UC326 insert on its own for replacement. Before packing, the factory checks the mounting torque, the fit of the insert in the housing, the radial clearance and that the base-to-centre height is consistent across the batch.

Rings are marked with a brand you are authorised to use, with the FULI brand, or left neutral, as your order states. The box is printed with the model, precision class and brand.

Inquiries that leave out the prefix or suffix letters are the usual cause of a wrong quote, so write the full designation, for example UCT326.

Typical applications

  • Belt conveyor take-up (tail) pulleys
  • Screw conveyors and bucket elevators
  • Chain and belt tensioning on agricultural machinery

FAQ

What shaft size does UCT326 fit?

A 130 mm shaft (5.1181 in).

What is the difference between UCT326 and UCT328?

UCT328 is the next size up, for a 140 mm shaft, with inner ring width B 145 mm (10 mm more), dimension H 415 mm (30 mm more) and dimension L 515 mm (50 mm more). Choose UCT328 when the shaft is larger or the load is higher; the housings are not interchangeable.

Which insert fits UCT326?

The UC326 insert (130 × 280 × 135 mm). It is sold on its own for replacement.

UCT326 or UCP326: which should I use?

Both hold the same UC326 insert on a 130 mm shaft. UCT326 is a take-up unit (d 130 · H 385 · L 465 mm); UCP326 is a pillow block unit (d 130 · H 180 · J 480 mm). Choose by how the bearing is fixed to the machine: a pillow block bolts to a surface parallel to the shaft, a flange to a face across it.

Does UCT326 come as a complete unit or insert only?

UCT326 is normally supplied as a complete unit (insert bearing already fitted in the housing). The insert can also be quoted separately if you are replacing only the bearing.

Where are the load ratings for UCT326?

Load ratings for UCT326 are being checked against FULI's catalog and are not shown on this page yet. Model pages with a "Load ratings & speed" table carry values from FULI's catalog.

Request a quote for UCT326

WhatsApp instead

Your inquiry goes to sales@fuli-bearings.com.

Email us Chat on WhatsApp