Pillow block bearing unit

UCP212 Bearing Dimensions

UCP212 pillow block bearing unit: 60 mm bore, 184 mm bolt centres, 69.8 mm centre height (FULI catalog). P212 housing + UC212 insert, size-equivalent codes.

UCP212 pillow block bearing unit — representative image

UCP212 specifications

Shaft diameter d 60 mm
Centre height H 69.8 mm
Base length L 241 mm
Bolt hole spacing J 184 mm
Overall height H0 138 mm
Insert width B 65.1 mm
Mounting bolt M16
Seal / shield options Sealed insert bearing (UC type) with cast iron housing
Material Insert: GCr15 chrome bearing steel (rings and rolling elements); housing: cast iron
Precision P0 (standard)
Radial clearance C0 (standard); C3 on request

Dimensions from FULI's catalog.

Load ratings & speed

Dynamic load rating Cr 52.5 kN
Static load rating C0r 36.0 kN
Limiting speed, shaft js7 / j7 2,400 rpm
Limiting speed, shaft h7 1,800 rpm
Weight 4.6 kg — approx.

Values from FULI's catalog; confirm for your application.

How to read the UCP212 designation

SegmentMeaning
UCInsert bearing with set-screw locking and spherical outside diameter
PPillow block (plummer block) housing
2200 series (light duty)
12Bore code 12 → 60 mm bore. ISO bore code (00–03 = 10/12/15/17 mm; 04 and above = code × 5 mm).

UCP212 interchange by brand

UCP212 is a housed unit: a UC212 insert bearing in a P212 housing. The insert bearing dimensions follow ISO and interchange between manufacturers. Housing dimensions such as bolt hole spacing can differ between the JIS and ISO versions of the same designation, so please confirm the mounting dimensions with us before ordering.

BrandDesignation
SKFUCP 212
TimkenUCP212
NTNUCP212D1
KoyoUCP212

Same size code; NTN adds D1 after the number. Confirm housing bolt spacing.

Brand numbers for UCP, UCF and UCFL units: Pillow Block Bearing Cross Reference.

Brand names are trademarks of their respective owners. FULI is not affiliated with, authorized by or endorsed by these companies. Part numbers are shown for interchange reference only. FULI dimensions, load ratings and speeds come from the FULI catalog.

UCP212 compared with nearby sizes and housings

UCP212 is a pillow block unit that holds the UC212 insert on a 60 mm shaft: centre height H 69.8 mm, base length L 241 mm and overall height H0 138 mm with M16 bolts.

The same 212 size is also made as UCF212 (square flange unit, d 60 · L 175 · J 143 mm). All of them take the same UC212 insert, so a worn insert can be changed without changing the housing type.

UCP211 is the next smaller size in the same series on this site: shaft d 55 mm (5 mm less), inner ring width B 55.6 mm (9.5 mm less), centre height H 63.5 mm (6.3 mm less), length L 219 mm (22 mm less), bolt spacing J 171 mm (13 mm less) and overall height H0 126 mm (12 mm less).

ModelTypeMain dimensionsWeight (kg)
UCP212pillow block unit (this page)d 60 · H 69.8 · J 184 mm4.6
UCP211pillow block unitd 55 · H 63.5 · J 171 mm3.3
UC212insert bearing60 × 110 × 65.1 mm (d × D × B)1.54
UCF212square flange unitd 60 · L 175 · J 143 mm—

Dimensions in mm from the model pages; weight from FULI's catalog, — = not listed on this site.

UCP212 weight, load ratings and speed

FULI's catalog gives about 4.6 kg for the complete unit, housing and insert together, so 100 pieces of UCP212 weigh about 460 kg before packing.

The catalog lists UCP212 with a dynamic load rating of 52.5 kN and a static load rating of 36.0 kN. Its speed limits depend on the shaft tolerance: 2,400 rpm on a js7 or j7 shaft and 1,800 rpm on an h7 shaft. A closer shaft fit holds the inner ring more evenly, which is why the js7 / j7 figure is higher.

Values from FULI's catalog; confirm for your application.

UCP212 dimensions in inches

The nearest common inch shaft size to the 60 mm bore of UCP212 is 2-3/8 in (60.33 mm), 0.33 mm larger than the bore, so UCP212 will not go on it. An inch shaft needs an inch bore insert. Inch bore versions are made for some sizes; ask us with the shaft size.

DimensionMillimetresInches
Shaft diameter d60 mm2.3622 in
Centre height H69.8 mm2.7480 in
Base length L241 mm9.4882 in
Bolt hole spacing J184 mm7.2441 in
Overall height H0138 mm5.4331 in
Insert width B65.1 mm2.5630 in

Converted at 1 in = 25.4 mm and rounded to four decimals. The bearing itself is made to the millimetre sizes.

Mounting UCP212 (general guidance)

General guidance, not a FULI specification: insert bearings slide onto the shaft rather than being pressed on, and are held by their locking device. A shaft ground or drawn to h7 is common; a closer shaft such as js7 or j7 suits higher speed. For UCP212 the catalog gives 2,400 and 1,800 rpm for the two cases.

The UC212 insert in UCP212 is locked by set screws in the extended inner ring. Housed-unit problems usually start at the set screws: if the inner ring is not held, it turns on the shaft and wears it. Tighten each screw to the torque in the mounting instructions, and check them again after the first hours of running.

Bolt UCP212 down with M16 bolts at 184 mm spacing on a flat, rigid face. Line up the two housings on a shaft before tightening the bolts fully, then lock the inserts, so the shaft is not bent between them.

Grease for UCP212

The insert in UCP212 is sealed on both sides and greased at the factory. If the housing has a grease fitting, add grease slowly through it while the shaft turns until a little fresh grease shows at the seals; general practice is to relubricate more often in wet or dusty places.

Greases for a stated temperature range can be specified on the order; for North America a range of −40 to 120 °C is often asked for.

How FULI supplies UCP212

FULI supplies UCP212 as a complete unit, or the UC212 insert on its own for replacement. Before packing, the factory checks the mounting torque, the fit of the insert in the housing, the radial clearance and that the base-to-centre height is consistent across the batch.

Rings are marked with a brand you are authorised to use, with the FULI brand, or left neutral, as your order states. The box is printed with the model, precision class and brand.

Inquiries that leave out the prefix or suffix letters are the usual cause of a wrong quote, so write the full designation, for example UCP212.

Typical applications

  • Conveyors
  • Fans and blowers
  • Agricultural machinery
  • Grain and food processing lines

FAQ

What shaft size does UCP212 fit?

A 60 mm shaft (2.3622 in).

Which insert fits UCP212?

The UC212 insert (60 × 110 × 65.1 mm). It is sold on its own for replacement.

UCP212 or UCF212: which should I use?

Both hold the same UC212 insert on a 60 mm shaft. UCP212 is a pillow block unit (d 60 · H 69.8 · J 184 mm); UCF212 is a square flange unit (d 60 · L 175 · J 143 mm). Choose by how the bearing is fixed to the machine: a pillow block bolts to a surface parallel to the shaft, a flange to a face across it.

How much does UCP212 weigh?

About 4.6 kg in FULI's catalog; 100 pieces weigh about 460 kg before packing.

Does UCP212 come as a complete unit or insert only?

UCP212 is normally supplied as a complete unit (insert bearing already fitted in the housing). The insert can also be quoted separately if you are replacing only the bearing.

Request a quote for UCP212

WhatsApp instead

Your inquiry goes to sales@fuli-bearings.com.

Email us Chat on WhatsApp