Flange bearing unit

UCF212 Bearing Dimensions

UCF212 4-bolt square flange bearing unit: 60 mm bore, 143 mm bolt centres. F212 housing + UC212 insert, designation, size-equivalent codes.

UCF212 flange bearing unit — representative image

UCF212 specifications

Shaft diameter d 60 mm
Flange length L 175 mm
Bolt hole spacing J 143 mm
Insert width B 65.1 mm
Mounting bolt M16
Seal / shield options Sealed insert bearing (UC type) with cast iron housing
Material Insert: GCr15 chrome bearing steel (rings and rolling elements); housing: cast iron
Precision P0 (standard)
Radial clearance C0 (standard); C3 on request
Load ratings Load ratings for this model are being checked against FULI's catalog. Ask for them with the quote.

Dimensions cross-checked against published catalogues; please confirm with your quote.

How to read the UCF212 designation

SegmentMeaning
UCInsert bearing with set-screw locking and spherical outside diameter
FFour-bolt square flange housing
2200 series (light duty)
12Bore code 12 → 60 mm bore. ISO bore code (00–03 = 10/12/15/17 mm; 04 and above = code × 5 mm).

UCF212 interchange by brand

UCF212 is a housed unit: a UC212 insert bearing in an F212 housing. The insert bearing dimensions follow ISO and interchange between manufacturers. Housing dimensions such as bolt hole spacing can differ between the JIS and ISO versions of the same designation, so please confirm the mounting dimensions with us before ordering.

BrandDesignation
SKFUCF 212
TimkenUCF212
KoyoUCF212

Same designation; confirm housing bolt spacing.

Brand numbers for UCP, UCF and UCFL units: Pillow Block Bearing Cross Reference.

Brand names are trademarks of their respective owners. FULI is not affiliated with, authorized by or endorsed by these companies. Part numbers are shown for interchange reference only. FULI dimensions, load ratings and speeds come from the FULI catalog.

UCF212 compared with nearby sizes and housings

UCF212 is a square flange unit that holds the UC212 insert on a 60 mm shaft: flange length L 175 mm with M16 bolts.

The same 212 size is also made as UCP212 (pillow block unit, d 60 · H 69.8 · J 184 mm). All of them take the same UC212 insert, so a worn insert can be changed without changing the housing type.

UCF213 is the next larger size in the same series on this site: shaft d 65 mm (5 mm more), inner ring width B 65.1 mm (the same), length L 187 mm (12 mm more) and bolt spacing J 149 mm (6 mm more).

UCF211 is the next smaller size in the same series on this site: shaft d 55 mm (5 mm less), inner ring width B 55.6 mm (9.5 mm less), length L 162 mm (13 mm less) and bolt spacing J 130 mm (13 mm less).

ModelTypeMain dimensionsWeight (kg)
UCF212square flange unit (this page)d 60 · L 175 · J 143 mm—
UCF211square flange unitd 55 · L 162 · J 130 mm—
UCF213square flange unitd 65 · L 187 · J 149 mm—
UC212insert bearing60 × 110 × 65.1 mm (d × D × B)1.54
UCP212pillow block unitd 60 · H 69.8 · J 184 mm4.6

Dimensions in mm from the model pages; weight from FULI's catalog, — = not listed on this site.

UCF212 load ratings

FULI's catalog has no load rating line for UCF212 itself, so none is given here. The ratings of the UC212 insert are on its own page. Ask us and we send the figures with the quotation.

UCF212 dimensions in inches

The nearest common inch shaft size to the 60 mm bore of UCF212 is 2-3/8 in (60.33 mm), 0.33 mm larger than the bore, so UCF212 will not go on it. An inch shaft needs an inch bore insert. Inch bore versions are made for some sizes; ask us with the shaft size.

DimensionMillimetresInches
Shaft diameter d60 mm2.3622 in
Flange length L175 mm6.8898 in
Bolt hole spacing J143 mm5.6299 in
Insert width B65.1 mm2.5630 in

Converted at 1 in = 25.4 mm and rounded to four decimals. The bearing itself is made to the millimetre sizes.

Mounting UCF212 (general guidance)

General guidance, not a FULI specification: insert bearings slide onto the shaft rather than being pressed on, and are held by their locking device. A shaft ground or drawn to h7 is common; a closer shaft such as js7 or j7 suits higher speed.

The UC212 insert in UCF212 is locked by set screws in the extended inner ring. Housed-unit problems usually start at the set screws: if the inner ring is not held, it turns on the shaft and wears it. Tighten each screw to the torque in the mounting instructions, and check them again after the first hours of running.

Bolt UCF212 down with M16 bolts at 143 mm spacing on a flat, rigid face. Line up the two housings on a shaft before tightening the bolts fully, then lock the inserts, so the shaft is not bent between them.

Grease for UCF212

The insert in UCF212 is sealed on both sides and greased at the factory. If the housing has a grease fitting, add grease slowly through it while the shaft turns until a little fresh grease shows at the seals; general practice is to relubricate more often in wet or dusty places.

Greases for a stated temperature range can be specified on the order; for North America a range of −40 to 120 °C is often asked for.

How FULI supplies UCF212

FULI supplies UCF212 as a complete unit, or the UC212 insert on its own for replacement. Before packing, the factory checks the mounting torque, the fit of the insert in the housing, the radial clearance and that the base-to-centre height is consistent across the batch.

Rings are marked with a brand you are authorised to use, with the FULI brand, or left neutral, as your order states. The box is printed with the model, precision class and brand.

Inquiries that leave out the prefix or suffix letters are the usual cause of a wrong quote, so write the full designation, for example UCF212.

Typical applications

  • Conveyors
  • Packaging machinery
  • Agricultural machinery
  • Textile machinery

FAQ

What shaft size does UCF212 fit?

A 60 mm shaft (2.3622 in).

What is the difference between UCF212 and UCF213?

UCF213 is the next size up, for a 65 mm shaft, with inner ring width B 65.1 mm (the same), length L 187 mm (12 mm more) and bolt spacing J 149 mm (6 mm more). Choose UCF213 when the shaft is larger or the load is higher; the housings are not interchangeable.

Which insert fits UCF212?

The UC212 insert (60 × 110 × 65.1 mm). It is sold on its own for replacement.

UCF212 or UCP212: which should I use?

Both hold the same UC212 insert on a 60 mm shaft. UCF212 is a square flange unit (d 60 · L 175 · J 143 mm); UCP212 is a pillow block unit (d 60 · H 69.8 · J 184 mm). Choose by how the bearing is fixed to the machine: a pillow block bolts to a surface parallel to the shaft, a flange to a face across it.

Does UCF212 come as a complete unit or insert only?

UCF212 is normally supplied as a complete unit (insert bearing already fitted in the housing). The insert can also be quoted separately if you are replacing only the bearing.

Where are the load ratings for UCF212?

Load ratings for UCF212 are being checked against FULI's catalog and are not shown on this page yet. Model pages with a "Load ratings & speed" table carry values from FULI's catalog.

Request a quote for UCF212

WhatsApp instead

Your inquiry goes to sales@fuli-bearings.com.

Email us Chat on WhatsApp