Insert bearing

UC202 Bearing Dimensions

UC202 insert bearing: 15 mm bore, 47 mm spherical OD, 31 mm width, set-screw lock. Fits P202/F202/FL202/T202 housings. Quote.

UC202 insert bearing — representative image

UC202 specifications

Bore d 15 mm
Outside diameter D 47 mm
Inner ring width B 31 mm
Outer ring width C 17 mm
Seal / shield options Sealed insert bearing (UC type), spherical outside diameter, set-screw locking
Material GCr15 chrome bearing steel (rings and rolling elements)
Precision P0 (standard)
Radial clearance C0 (standard); C3 on request
Load ratings Load ratings for this model are being checked against FULI's catalog. Ask for them with the quote.

Dimensions cross-checked against published catalogues; please confirm with your quote.

How to read the UC202 designation

SegmentMeaning
UCInsert bearing with set-screw locking and spherical outside diameter
2200 series (light duty)
02Bore code 02 → 15 mm bore. ISO bore code (00–03 = 10/12/15/17 mm; 04 and above = code × 5 mm).

UC202 interchange

UC202 is an ISO designation. The boundary dimensions are identical across manufacturers; only suffixes (seals, clearance, cage) differ.

Brand numbers for UCP, UCF and UCFL units: Pillow Block Bearing Cross Reference.

Brand names are trademarks of their respective owners. FULI is not affiliated with, authorized by or endorsed by these companies. Part numbers are shown for interchange reference only. FULI dimensions, load ratings and speeds come from the FULI catalog.

UC202 compared with nearby sizes and housings

UC202 is a set-screw insert for a 15 mm shaft: outside diameter 47 mm, inner ring width 31 mm and outer ring width 17 mm.

The UC202 insert is the one fitted in UCP202 (pillow block unit). Other inserts with the same size code are SB202 (15 × 40 × 22 mm) and SA202 (15 × 40 × 19.1 mm).

UC203 is the next larger size in the same series on this site: shaft d 17 mm (2 mm more), outside diameter D 47 mm (the same) and inner ring width B 31 mm (the same).

UC201 is the next smaller size in the same series on this site: shaft d 12 mm (3 mm less), outside diameter D 47 mm (the same) and inner ring width B 31 mm (the same).

ModelTypeMain dimensionsWeight (kg)
UC202insert bearing (this page)15 × 47 × 31 mm (d × D × B)—
UC201insert bearing12 × 47 × 31 mm (d × D × B)—
UC203insert bearing17 × 47 × 31 mm (d × D × B)—
SB202insert bearing15 × 40 × 22 mm (d × D × B)—
SA202insert bearing15 × 40 × 19.1 mm (d × D × B)—
UCP202pillow block unitd 15 · H 30.2 · J 95 mm—

Dimensions in mm from the model pages; weight from FULI's catalog, — = not listed on this site.

UC202 load ratings

FULI's catalog has no load rating line for UC202 itself, so none is given here. Ask us and we send the figures with the quotation.

UC202 dimensions in inches

The nearest common inch shaft size to the 15 mm bore of UC202 is 9/16 in (14.29 mm), 0.71 mm smaller than the bore, so UC202 would be loose on it. An inch shaft needs an inch bore insert. Inch bore versions are made for some sizes; ask us with the shaft size.

DimensionMillimetresInches
Bore d15 mm0.5906 in
Outside diameter D47 mm1.8504 in
Inner ring width B31 mm1.2205 in
Outer ring width C17 mm0.6693 in

Converted at 1 in = 25.4 mm and rounded to four decimals. The bearing itself is made to the millimetre sizes.

Mounting UC202 (general guidance)

General guidance, not a FULI specification: insert bearings slide onto the shaft rather than being pressed on, and are held by their locking device. A shaft ground or drawn to h7 is common; a closer shaft such as js7 or j7 suits higher speed.

UC202 is locked by set screws in the extended inner ring. Housed-unit problems usually start at the set screws: if the inner ring is not held, it turns on the shaft and wears it. Tighten each screw to the torque in the mounting instructions, and check them again after the first hours of running.

The spherical outside diameter of UC202 lets the insert swivel in the housing seat while it is being mounted, which takes up small errors in shaft line. It does not make the bearing a self-aligning bearing in service.

Grease for UC202

The insert is sealed on both sides and greased at the factory. Fitted in a housing with a grease fitting, it can be relubricated through the housing; on its own it runs on the factory fill.

Greases for a stated temperature range can be specified on the order; for North America a range of −40 to 120 °C is often asked for.

How FULI supplies UC202

FULI supplies UC202 on its own as a replacement insert, or fitted in a housing as a complete unit. The rings and balls are GCr15 chrome steel and the radial clearance is C0 as standard, with C3 on request.

Rings are marked with a brand you are authorised to use, with the FULI brand, or left neutral, as your order states. The box is printed with the model, precision class and brand.

Inquiries that leave out the prefix or suffix letters are the usual cause of a wrong quote, so write the full designation, for example UC202.

Typical applications

  • Replacement inserts for UCP / UCF / UCFL housings
  • Conveyors
  • Agricultural machinery

FAQ

What shaft size does UC202 fit?

A 15 mm shaft (0.5906 in).

What is the difference between UC202 and UC203?

UC203 is the next size up, for a 17 mm shaft, with outside diameter D 47 mm (the same) and inner ring width B 31 mm (the same). Choose UC203 when the shaft is larger or the load is higher; the housings are not interchangeable.

Which housings fit the UC202 insert?

UCP202 (pillow block unit) all use UC202. Order UC202 on its own to replace a worn insert in any of them.

What is the difference between UC202 and SB202?

Both fit a 15 mm shaft with a 47 mm outside diameter. UC202 has an inner ring 31 mm wide and SB202 22 mm. Both lock with set screws. Check that the narrower or wider ring clears the housing and the parts beside it on the shaft.

Can UC202 be ordered as an insert only, or as a complete unit?

Both. UC202 can be supplied on its own as a replacement insert for an existing housing, or fitted in a housing such as the UCP202 pillow block or UCF202 square flange and supplied as a complete unit. Tell us which you need when you send the inquiry.

Where are the load ratings for UC202?

Load ratings for UC202 are being checked against FULI's catalog and are not shown on this page yet. Model pages with a "Load ratings & speed" table carry values from FULI's catalog.

Request a quote for UC202

WhatsApp instead

Your inquiry goes to sales@fuli-bearings.com.

Email us Chat on WhatsApp